C-Tec XFP501E-CA XFP 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST protocol)

C-Tec XFP501E-CA XFP 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST protocol)

PROTOCOL FEATURES:

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase, its key features include:

• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.
• Designed and manufactured in the UK.

PANEL FEATURES:

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers.
• An integral EN54-4/A2 switch mode.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / keyswitch entry to Access Levels 2 and 3.
• 500 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Technical Specifications:
Protocol/compatibility

C-TEC CAST.

Mains supply

230V 50/60Hz.

Mains rated current

350mA maximum.

Internal power supply

27Vdc nominal.

Total output current limited to

1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).

Quiescent current

50mA (loop unloaded).

Max battery size and type

2 x 12V 3.2Ah VRLA connected in series.

No. of loop drivers

1.

Max. loop output current

450mA (40V max).

Max. loop length

1KM.

Max. addressable devices per loop

255.

No. of conventional sounder circuits

2 (Max. length per circuit is 500m).

EOL resistor value

6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

Max. sounder output current

400mA.

Auxiliary relays

3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.

Other outputs

24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.

Auxiliary inputs

2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).

PC connection

PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.

Indicators

2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst

Connections

Fixed, largest acceptable conductor size 1mm2.

Expansion connections

2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or

Product dimensions (mm)

380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required).

Construction & finish

Plastic lid and base; RAL7035 textured

IP Rating

IP30.

$422.27
C-Tec XFP501E-CA XFP 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST protocol)
$422.27
Product image 1

Description

PROTOCOL FEATURES:

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase, its key features include:

• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.
• Designed and manufactured in the UK.

PANEL FEATURES:

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers.
• An integral EN54-4/A2 switch mode.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / keyswitch entry to Access Levels 2 and 3.
• 500 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Technical Specifications:
Protocol/compatibility

C-TEC CAST.

Mains supply

230V 50/60Hz.

Mains rated current

350mA maximum.

Internal power supply

27Vdc nominal.

Total output current limited to

1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).

Quiescent current

50mA (loop unloaded).

Max battery size and type

2 x 12V 3.2Ah VRLA connected in series.

No. of loop drivers

1.

Max. loop output current

450mA (40V max).

Max. loop length

1KM.

Max. addressable devices per loop

255.

No. of conventional sounder circuits

2 (Max. length per circuit is 500m).

EOL resistor value

6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

Max. sounder output current

400mA.

Auxiliary relays

3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.

Other outputs

24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.

Auxiliary inputs

2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).

PC connection

PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.

Indicators

2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst

Connections

Fixed, largest acceptable conductor size 1mm2.

Expansion connections

2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or

Product dimensions (mm)

380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required).

Construction & finish

Plastic lid and base; RAL7035 textured

IP Rating

IP30.

C-Tec XFP501E-CA XFP 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST protocol) | Electrical Wholesalers 4 U